Failure and rectification of single ply membranes

Inspection of synthetic single ply membranes and composite materials that include the roof deck and insulation (Topdec Membrane Roof ), for correct and compliant installation and fixing methods.

Physical lap integrity testing and probing of welded joints.

Opening up of defective membranes and attachment of mechanically fixed systems and bonded systems and condition and compliance of lap welding of PVC, TPE and TPE type materials with options of electronic testing if the membranes are suitable for this type of testing.

EPDM or rubber based materials and Topdek materials are not suitable for electronic testing and other methods are required to obtain tangible results.

Material testing is offered for these types of material.